Product details
Product Overview: Rockfall Protection Net (Active and Passive)
A rockfall protection net is a flexible system. It does not resist impact rigidly; it absorbs energy by letting the mesh deform and letting the dissipating elements fail first, stage by stage. There are two families by position. Active nets are draped over the slope and pressed onto it with rope anchors, so the rock mass is restrained and shallow sliding is prevented before any block is released. Passive nets stand at the toe or in the rockfall path: steel posts, support ropes and braking rings form a barrier that yields, catching the block in the mesh while the rings break and absorb the energy, leaving the posts and foundations intact.
An active system is a continuous load path. Diamond steel-rope mesh is laid on the slope; double-strand phi 16 rope anchors are drilled into rock, typically 2-3 m long with a pull-out capacity of at least 50 kN; phi 16 horizontal and phi 16 or phi 12 vertical support ropes tie the panels together; phi 8 lacing rope stitches the panel edges hole by hole. Where small rock or soil must be held, a wire grid is added behind the rope mesh, which is the GPS2 double-layer arrangement; for higher demand, a high-strength steel-wire grid such as TECCO grade (wire strength around 1770 N/mm²) replaces the ordinary grid.
A passive system is organised around one question: how much energy must it stop? Ring nets or rope nets form the catching face; I-beam posts are erected at a spacing commonly 10 m; upper and lower support ropes plus upslope, side and downslope anchor ropes tie net to posts and posts to foundation; braking rings are fitted on support and anchor ropes according to the model. When impact exceeds the threshold the rings break and dissipate energy, sacrificing a component to keep the posts and foundation. The digits in RXI-050, 075, 100, 150 and 200 denote the energy class - the larger the number, the higher the kinetic energy that can be arrested, and the heavier the posts, ropes and ring count.
Fix the selection sequence in three steps: decide whether the source is on the slope or at the toe, which sets active or passive; then set the model and energy class from the surveyed block size, fall height and impact energy; finally set anchor length, pull-out capacity and foundation type from the ground conditions. Quoting by area per square metre while skipping the first two steps is the most common source of failure.
Specifications and Parameters (Active System):
| Item | Specification |
|---|---|
| Mesh | Diamond steel-rope mesh, phi 8 mm rope, aperture commonly 300 x 300 mm; wire grid or high-strength grid may be added |
| Anchors | Double-strand phi 16 mm rope anchors, typically 2-3 m long, pull-out capacity not less than 50 kN (to be confirmed by design) |
| Support Ropes | Horizontal phi 16 mm; vertical phi 16 mm or phi 12 mm |
| Lacing Rope | phi 8 mm |
| System Models | GPS1 (single rope mesh), GPS2 (rope mesh plus grid), GAR / GER series according to slope condition |
| Surface Treatment | Hot-dip galvanized, zinc requirement to be agreed per project |
| Typical Location | Shallow sliding slopes, source zones, blasting fly-rock, tunnel portal slopes |
Specifications and Parameters (Passive System):
| Item | Specification |
|---|---|
| Model and Energy | RX / RXI-050, 075, 100, 150, 200 (digits x 100 give the energy class; to be confirmed by design) |
| Catching Face | Ring net (ring diameter commonly 300 mm, 3 or 5 turns) or diamond rope mesh; add wire grid for small rock |
| Posts | I-beam steel posts, height and section per model; spacing commonly 10 m |
| Ropes | Upper and lower support ropes plus upslope, side and downslope anchor ropes (single or double per model) |
| Braking Rings | Fitted on support and anchor ropes, quantity per model; break under overload to protect posts and foundation |
| Foundation | Concrete or anchor foundation designed to the ground conditions and pull-out requirement |
| Surface Treatment | Hot-dip galvanized, zinc requirement to be agreed per project |
| Typical Location | Slope toe, rockfall channels, tunnel portals, bridge heads, below cut slopes |
Active or Passive - Selection Comparison:
| Item | Active System | Passive System |
|---|---|---|
| Mechanism | Restrains the rock mass, stops blocks from releasing | Catches released blocks and absorbs kinetic energy |
| Position | Draped on the slope and anchored to rock | At the toe or in the path, on independent posts |
| Key Parameter | Anchor pull-out capacity, panel and anchor strength | Energy class, number of braking rings |
| Footprint | Practically none | Space needed at the toe for catching and debris |
| Maintenance | Inspect anchor heads and lacing, patch locally | Clear debris, replace rings and damaged panels |
| Cost Driver | Area and anchor count | Energy class and post count |
| Typical Site | Source zones, shallow sliding slopes, portal slopes | Slope toe, bridge heads, portals, road-side channels |
Product Features:
- ● Yielding rather than rigid: mesh deformation and braking rings take the impact, which suits seismic and freeze-thaw conditions.
- ● Graded range: active systems by single or double layer and grid type; passive systems from class 050 to 200, matched to the rockfall energy instead of always specifying the top grade.
- ● Low construction disturbance: factory-made components, anchored and tensioned on site, with no massive concrete works and no long road closure.
- ● Permeable: the open mesh does not block slope drainage or vegetation, reducing secondary instability caused by trapped water.
- ● Repairable in parts: damage is usually a panel or a few rings, replaced individually without rebuilding the system.
- ● Monitoring ready: anchor heads and posts can carry displacement or load sensors and be integrated into a slope monitoring system.
Application Scenarios:
- ● Highway and railway cut slopes: active facing on the slope, passive interception at the toe, combined with retaining walls and catch drains.
- ● Tunnel portals and portal slopes: covering the slope above the portal to keep rock out of the running clearance.
- ● Mines and quarries: bench slopes and blasting fly-rock zones.
- ● Reservoir and river banks: shallow sliding in the drawdown zone, where permeability avoids blocking drainage.
- ● Scenic and mountain roads: visually open, preserving the landscape character.
- ● Bridge heads and culvert inlets: intercepting rock on abutment side slopes and above culverts.
- ● Rehabilitation of existing protection: flexible systems added where earlier masonry protection has failed.
Frequently Asked Questions:
Company profile

Company profile
View more+Our advantages
18 years of export experience
Quality Certification
OEM/ODM support
Quality Certification
OEM/ODM support
Quality CertificationPackaging Logistics

-
air freight -
sea freight -
Trucking