Product details
Product Overview: Workshop Barrier Mesh
Workshop barrier mesh is modular by design: one panel, one post and two clips draw a boundary. The panel carries a metal frame with a low-carbon steel wire face, posts are 50 x 50 mm square tube 2 m long, and panels connect to posts with clips or bolts. Corners, gate openings and three-way junctions all have matching fittings, so no site welding is needed. When a production line moves or a warehouse zone is re-planned, the system is taken apart and re-assembled instead of being scrapped - which matters most in rented buildings where the floor must be left intact.
Four versions divide the work by what is being separated, and choosing the wrong version costs more than a price difference. General workshop mesh separates zones and walkways at 50 x 50 to 50 x 200 mm apertures - open, unobstructed for patrolling. Warehouse mesh separates storage positions from forklift aisles, usually with a swing or sliding gate and position signage, at a height set by rack level and forklift lift. Robot cell mesh guards the machine's working envelope: apertures close down to 20 x 100 mm or finer, not to stop a person climbing but to stop chips, tools and fingers. Perforated panel barrier separates sight and wind, using a perforated metal sheet instead of wire - flat, paintable, and able to block the view and dust from the opposite side.
Selection runs in three steps: decide whether you are separating people, vehicles, a machine envelope or sightlines; then set the aperture - fine mesh for the envelope, general mesh for walkways, perforated panel where screening is needed; finally fix the mounting, flange base with expansion bolts on hard floor, embedded on soil. The second step is where most projects go wrong: a 50 x 50 mm mesh on a robot cell lets small ejected parts straight through, which defeats the purpose.
Specifications and Parameters (General Workshop Mesh):
| Item | Specification |
|---|---|
| Frame and mesh | Metal frame, low-carbon steel wire face |
| Panel width | 0.5 m - 2.4 m |
| Panel height | 1.0 m - 2.4 m |
| Aperture | 50 x 50, 60 x 60, 20 x 100, 50 x 100, 50 x 200 mm |
| Posts | 50 x 50 mm square tube, 2 m overall length |
| Surface treatment | Galvanized, powder coated or PVC dipped; colours to order, including industrial green, grey and black-yellow warning |
| Connection | Clips or bolts; corner, tee and gate fittings supplied; no site welding |
| Mounting | Flange base with expansion bolts (hard floor) or embedded (soil), to be confirmed per project |
Specifications and Parameters (Robot Cell Fine Mesh):
| Item | Specification |
|---|---|
| Application | Working envelope of industrial robots and automation lines |
| Aperture | 20 x 100 mm fine mesh; finer 5 - 20 mm available to order, to be confirmed |
| Panel construction | Fine welded or woven mesh in a metal frame; safety gate and lock optional |
| Panel size | Laid out to the guarded envelope; heights commonly 1.8 m or 2.0 m, to be confirmed |
| Posts | 50 x 50 mm square tube; closer spacing recommended around the envelope |
| Surface treatment | Galvanized plus powder coating, in warning colours or matched to the machine |
| Options | Warning signage, viewing window, mounting for safety door switches, cable trunking |
Specifications and Parameters (Perforated Panel Barrier):
| Item | Specification |
|---|---|
| Panel | Perforated metal sheet (galvanized, aluminium or stainless); thickness 0.8 - 2.0 mm, not less than 1.5 mm for 2 m height |
| Hole size | 5 - 10 mm for guarding, 15 - 20 mm for decorative; hole should not be smaller than sheet thickness |
| Open area | 15% - 50% (30% - 50% for ventilation, 15% - 35% for decorative screening) |
| Wind performance | Air permeability about 30% - 50%; wind pressure roughly 60% of a solid hoarding of the same area |
| Sheet size | 1.2 x 2.4 m or 1.25 x 2.5 m; about 30 mm unperforated margin left for folding |
| Structure | Folded-edge type (the folded edge is the frame, no separate frame member) or framed type (sheet set into or welded to a square tube frame) |
| Folding limit | Distance from hole edge to the centre of the bend radius L >= 2t (t = sheet thickness), otherwise holes deform or tear |
| Posts | 60 x 60 or 100 x 100 mm square tube, wall 1.5 - 3.0 mm, or Ø48 mm round tube; post spacing not more than 2.5 m |
| Mounting | Embedded not less than 0.5 m, or flange base on hard floor, to be confirmed |
| Surface treatment | Galvanized plus powder coating; stainless may be left natural or brushed |
Specifications and Parameters (Warehouse Mesh):
| Item | Specification |
|---|---|
| Application | Storage position division, forklift and pedestrian separation, quarantine and reject area enclosure |
| Panel height | 1.0 - 2.4 m, set by rack level and forklift lift height |
| Aperture | 50 x 50 and 50 x 100 mm mainly, balancing visibility and containment of items |
| Gate type | Swing gate or double sliding gate to aisle width; lock and access control optional |
| Accessories | Position sign holders, impact corner protectors, corner posts, aisle signage (per project) |
| Posts and mounting | 50 x 50 mm square tube; flange base on hard floor, denser posts at aisle ends |
Selecting Version and Aperture by What Is Being Guarded:
| Guarded against | Recommended version | Aperture / panel type | Cost of choosing wrong |
|---|---|---|---|
| Casual entry, zone division | General workshop mesh | 50 x 50, 50 x 100, 50 x 200 mm | Tighter mesh than needed wastes cost and reduces visibility |
| Forklifts, AGVs and people | Warehouse mesh with gates | 50 x 50, 50 x 100 mm | Without a gate the aisle is cut and the fence must be rebuilt |
| Robot chips, tools, fingers | Robot cell fine mesh | 20 x 100 mm, finer 5 - 20 mm if needed | 50 x 50 mm lets small parts through, so there is no protection |
| Sight, dust, splash | Perforated panel barrier | 5 - 10 mm holes (guarding) or 15 - 20 mm (decorative) | Wire mesh does not screen, so a blind must be added |
| Windy perimeter | Perforated panel, 30 - 50% open area | Higher open area gives better airflow | A solid hoarding raises wind pressure, so posts and footings must grow |
Posts and Mounting:
| Mounting | Method | Used for | Note |
|---|---|---|---|
| Flange base with expansion bolts | Flange welded to the post foot, four holes drilled and anchored | Concrete floor, hard-standing shops, rented buildings, layouts that change | Filling the holes restores the floor; weaker against lateral impact than embedding, so tighten post spacing at aisles |
| Embedded | Post foot cast into a concrete footing | Soil, planting areas, outdoor yards, permanent zoning | Depth confirmed per project and soil; relocation means breaking out the footing |
| Post section | 50 x 50 mm square as standard; 60 x 60 or 100 x 100 (wall 1.5 - 3.0 mm) for perforated panels | By panel height and wind load | Taller panels, wider spacing and higher wind all push section and wall up |
Comparison of the Four Versions:
| Version | Visibility | What It Guards | Structural Point |
|---|---|---|---|
| General workshop mesh | Open, patrol sightlines clear | Zone and walkway separation, casual entry | Panel plus 50 x 50 post, clip connection, re-usable |
| Warehouse mesh | Open, easy stocktaking | Storage order, forklift and pedestrian separation | Gate and signage, denser posts at aisle ends |
| Robot cell fine mesh | Reasonably open, machine visible | Chips, tools, fingers entering the envelope | 20 x 100 mm or finer, framed, safety gate lock |
| Perforated panel | Semi-screened, blocks view and dust | Visual screening, wind, dust and splash | Folded or framed type; open area and thickness set strength and airflow |
Common Accessories:
| Accessory | Function | Recommendation |
|---|---|---|
| Clips and connectors | Panel-to-post connection | Supplied as standard; dedicated parts for corners, tees and ends |
| Swing or double sliding gate | Through access | Width set by what passes: people, forklifts or AGVs; gate posts braced or more densely fixed |
| Safety switch bracket | Stops the machine when the gate opens | Required for robot and automation guarding |
| Corner and end posts | Corner and end loading | One size larger section |
| Impact corner protector | Protects posts at forklift aisles | Recommended for warehouse and logistics areas |
| Position sign holder and warning signs | Zoning and safety marking | To the site 5S and safety colour code |
| Viewing window | Observe the machine through fine mesh | Set at eye height and distinguishable from warning colour |
Product Features:
- ● Modular and re-usable: panels, posts, clips and gate parts are standard, so a layout change is a rebuild rather than scrap.
- ● Floor-friendly: flange base with expansion bolts, so a tenancy can be restored by filling a few holes.
- ● Daylight friendly: a high open area removes the need for extra lighting and keeps vehicles and pedestrians visible.
- ● Easy to clean: no ledges or cavities, so air or water cleaning suits 5S and clean-room discipline.
- ● Graded protection: from general 50 x 50 mm to fine 20 x 100 mm and finer, matched to the hazard rather than always specifying the tightest mesh.
- ● Custom finish: galvanized, powder coated or dipped, in corporate colours or the site safety code.
Application Scenarios:
- ● Machining and assembly shops: line segregation, machine operating zones, separation of pedestrian and logistics routes.
- ● Warehouses and distribution centres: storage positions, quarantine and reject areas, forklift aisle edges.
- ● Robot and automation cells: enclosure of the working envelope, load and unload openings, maintenance access.
- ● Switch rooms and plant rooms: protection of precision cooling units, panels and compressors against accidental contact.
- ● Factory perimeter and gatehouses: internal secondary separation and temporary control zones.
- ● Market stalls and exhibition stands: quick partitions and display enclosures.
- ● Construction and maintenance work fronts: temporary isolation of hazardous work areas with warning colours and signage.
Installation and Acceptance Points:
Setting out: mark the zone lines and post positions from the plan, fix gate openings and clear aisle widths first, then set post spacing. A misplaced gate opening forces the whole run to be re-set, and that is the commonest rework on site.
Post spacing: normally matched to panel width, tightened at aisles, corners and either side of gate posts. Excessive spacing lets the panel middle flex, and a forklift brush is enough to pop the clips.
Base plates: drill four holes and torque the expansion anchors as specified - never fit only two. Where the slab is weak, use chemical anchors or a larger base plate, and state this at quotation stage.
Assembly: stand the two end posts with temporary bracing, line and plumb them, then hang panels in sequence and lock the clips. Leave a 20 - 50 mm gap between panel and floor for washing down and to keep the post foot out of standing water.
Acceptance: check three things - post plumb, clip count at every intersection, and gate operation without sag. On machine guarding, also verify that the safety switch interlock stops the machine.
Availability note: this series is a standard supporting category and the four versions can be arranged in normal sizes. Finer 5 - 20 mm mesh, non-standard heights, special colours and large gate quantities need factory confirmation of feasibility and method. Please confirm the exact specification, minimum quantity and lead time with our sales team.
Frequently Asked Questions:
Company profile

Company profile
View more+Our advantages
18 years of export experience
Quality Certification
OEM/ODM support
Quality Certification
OEM/ODM support
Quality CertificationPackaging Logistics

-
air freight -
sea freight -
Trucking